quotation:[Copy]
H. Sira Ramˇrez,A. Hern,ez MEndez,J. Linares Flores,A. Luviano Juarez.[en_title][J].Control Theory and Technology,2016,14(3):224~236.[Copy]
【Print page】 【Online reading】【Download 【PDF Full text】 View/Add CommentDownload reader Close

←Previous page|Page Next →

Back Issue    Advanced search

This Paper:Browse 1673   Download 1280 本文二维码信息
码上扫一扫!
Robust flat filtering DSP based control of the boost converter
H.Sira Ramˇrez,A.HernandezMEndez,J.LinaresFlores,A.LuvianoJuarez
0
(Department of Electrical Engineering, Mechatronics Section, CINVESTAV-IPN)
摘要:
The article deals with the design and implementation of a flat filter tracking digital controller for a boost dc-dc power converter. A highly perturbed switched boost converter circuit is shown to be efficiently controlled, in a trajectory tracking task for its non-minimum phase output, by means of a suitable linear filter, here addressed as a flat filter. Flat filtering is a natural robust version of generalized proportional integral control (GPIC) by which the effects of arbitrary time varying exogenous disturbances, unknown endogenous nonlinearities and un-modeled dynamics can be jointly attenuated in a conceptually similar fashion to observer-based active disturbance rejection control (ADRC) and algebraic identification based model free control (MFC) but: a) without using extended state observers and b) respecting the original system order in a time-varying simplified model while avoiding algebraic estimation techniques. The proposed control technique based on the TMS320F28335 digital signal processor chip is tested by means of realistic simulations and experimental setup.
关键词:  Flat filter, DSP-implementation, boost converter
DOI:
Received:February 10, 2016Revised:May 07, 2016
基金项目:
Robust flat filtering DSP based control of theboost converter
H. Sira Ramˇrez,A. Hernandez MEndez,J. Linares Flores,A. Luviano Juarez
(Department of Electrical Engineering, Mechatronics Section, CINVESTAV-IPN;Universidad Tecnolo′gica de la Mixteca;UPIITA-IPN)
Abstract:
The article deals with the design and implementation of a flat filter tracking digital controller for a boost dc-dc power converter. A highly perturbed switched boost converter circuit is shown to be efficiently controlled, in a trajectory tracking task for its non-minimum phase output, by means of a suitable linear filter, here addressed as a flat filter. Flat filtering is a natural robust version of generalized proportional integral control (GPIC) by which the effects of arbitrary time varying exogenous disturbances, unknown endogenous nonlinearities and un-modeled dynamics can be jointly attenuated in a conceptually similar fashion to observer-based active disturbance rejection control (ADRC) and algebraic identification based model free control (MFC) but: a) without using extended state observers and b) respecting the original system order in a time-varying simplified model while avoiding algebraic estimation techniques. The proposed control technique based on the TMS320F28335 digital signal processor chip is tested by means of realistic simulations and experimental setup.
Key words:  Flat filter, DSP-implementation, boost converter